Fault guide · tripping

Power keeps tripping in Singapore — read the pattern before you reset it

A breaker that trips is reporting a fault. Whether it is one MCB or the main RCCB, and whether it trips instantly, under load or randomly, decides what has to be tested — and whether you need a part, a circuit repair or an insulation test.

If one MCB trips instantly every time you reset it, the fault is on that circuit: usually an appliance, a socket or a cable. If the main switch or RCCB trips, suspect insulation, moisture or a shared neutral, and expect insulation testing rather than a simple part swap. Either way, stop resetting it and keep the circuit off until it is tested.

What a trip is actually telling you

An MCB protects the cable, not the appliance. It trips when current is too high for too long, or when there is a short circuit. An RCCB (often labelled with a test button) trips when current is leaking to earth — through water, damaged insulation or a faulty element. Those are two different investigations, and they cost differently.

What you seeMost likelyWhat the job involves
MCB trips instantly after reset, nothing plugged inShort circuit or damaged cable on that circuitInsulation test on the circuit, then repair or rewire the affected run
MCB trips when a kettle, heater or aircon startsAppliance fault or circuit close to its ratingTest the appliance; check cable size and breaker rating before adding load
Main switch or RCCB trips, MCBs stay upEarth leakage: moisture, damaged insulation or a shared neutralInsulation resistance test, split the circuits, isolate the leaking one
Trips after rain or after hot water useWater ingress at an outdoor point, heater or riserInspect and dry the affected enclosure, replace damaged accessories
Trips randomly, sometimes days apartIntermittent load, loose termination or a failing applianceLonger diagnostic slot with load testing; ask what was running
Half the flat is dead, nothing trippedSupply-side or main connection issue, or a hidden RCD/switchCheck the DB and supply side before assuming an internal fault

Safe checks you can do without tools

  • Look at the DB without opening the cover: note which switch is down and read its label.
  • Unplug the appliance that was running when it tripped, then reset the circuit once.
  • Check whether other units or floors are affected — that changes who owns the fault.
  • Photograph the board labels; the label often names the circuit more accurately than memory.
Do not: hold a breaker up, tape it on, replace it with a bigger rating, or keep resetting a breaker that trips instantly. Do not open a DB cover or touch a wet switch. If there is a burning smell, heat or smoke, isolate at the main switch and call 995 if there is fire.

What to photograph for a quote

  • One wide photo of the DB with the labels legible.
  • One close photo of the tripped switch and its label.
  • The appliance or socket that was in use when it tripped.
  • Any water staining, discolouration or heat marks near the point.

Who attends and how it is priced

Tripping diagnosis and repair is licensed electrical work. AOT coordinates the visit; an EMA-licensed consortium partner carries out testing, isolation and repair within the scope of their licence. A single-circuit fault is usually one diagnostic visit plus parts. If insulation testing or a new circuit is required, we quote that after the test rather than guessing on the phone.

Why we do not quote a fixed price on the phone: the same symptom can be a $15 accessory or a damaged cable run behind a wall. A number given before testing is either padded or wrong; both cost you more.

Questions owners and managers ask

Why does my breaker trip only at night?

Night-time trips usually follow a load that runs at night — a water heater, air-conditioning or a neighbour-shared circuit. If the pattern is genuinely random, the cause is more often a loose termination or a failing appliance than the breaker itself, and it needs a longer diagnostic slot.

Can I just replace the breaker with a bigger one?

No. The breaker is sized to protect the cable. Fitting a larger one lets the cable overheat before the breaker acts, which is how fires start. If the circuit trips because of load, the answer is a new circuit or redistributed load, not a bigger breaker.

What is the difference between an MCB, an RCCB and an ELCB?

An MCB protects against overload and short circuit. An RCCB detects earth leakage and protects people. ELCB is an older term still used by many Singapore households for what is now usually an RCCB. The label and the test button tell you which you have.

Does a tripping circuit mean I need to rewire the flat?

Usually not. Most trips are an appliance, an accessory or one damaged cable section. Full rewiring is considered when insulation tests fail across multiple circuits or the wiring is old and brittle throughout.

Can AOT attend today?

We offer the next available slot, usually same or next business day during Mon–Sat 08:00–17:00. We do not promise 24/7 attendance or a 30-minute arrival, because we would rather be accurate than fast on paper.

Need this looked at properly?

Send three photos and the pattern. We confirm scope, who attends and a price band before anyone travels. Mon–Sat 08:00–17:00.