Why does my power trip only when the aircon runs?
A breaker that trips only when the aircon starts is usually reporting one of two faults: earth leakage from a wet outdoor unit or a failing compressor winding, or a genuine overload from compressor starting current on a shared or undersized circuit. The first thing to read is which device tripped — the 30 mA RCCB or that circuit's MCB.
Updated 6 Nov 2026 · AOT Electrical, a trade site of ALPHA & OMEGA TRINITY PTE. LTD. (UEN 201215586K)
The aircon is the only load that pulls a start-up surge and sits next to water
Two faults look identical from the sofa — the moment the aircon switches on, the power goes. They are not the same fault and they are not fixed by the same work. Read which device dropped before touching anything.
| What you notice | What it usually means | What we test |
|---|---|---|
| The whole flat goes dark and the main RCCB (the one with the test button) drops | Earth leakage — current escaping to earth through the unit, its isolator or a wet enclosure | Insulation resistance on the aircon circuit with the isolator off, then isolated and tested again at the unit |
| Only the aircon MCB trips; the rest of the flat stays on | Overload or short circuit on that one circuit | Clamp the running current against the MCB rating, then check the compressor's starting current and the cable size |
| Holds for a few minutes, then trips — every time | Heat-related leakage: a winding or terminal that only faults once it is warm and drawing | Megger test cold, then watch the running current as the unit warms up |
| Trips only when it rains, or after a chemical wash | Water in the outdoor isolator, terminal box or cable entry | Open every outdoor enclosure, check the drain path and cable gland, dry and re-test |
| Trips when the aircon and another heavy load run together | Shared circuit or a board that is already near capacity | Map the board, add up the connected load, confirm which circuit feeds the aircon |
| Outdoor fan not turning, or a buzzing from the unit before the trip | Seized fan motor or a failing start capacitor drawing locked-rotor current | Test the capacitor and motor winding — swapping the breaker will not fix either |
Why starting current is the tell
An aircon compressor draws several times its running current for the first second it starts. On a circuit that also feeds other points, or one that was sized for an older, smaller unit, that surge can be enough to trip the MCB — and it will only happen on start, never while the unit is running quietly. That is an overload question, answered with a clamp meter and the board's circuit map, not by fitting a bigger breaker.
If the main RCCB drops instead, the current is going somewhere it should not: a compressor winding, a terminal box that has taken in water, or an outdoor isolator sitting in a puddle after a chemical wash. That is a leakage question, and it is answered with insulation resistance.
What happens when you engage AOT
- Send two photos. The DB with the tripped switch visible, and the aircon unit or outdoor isolator. Diagnosis is quoted from S$60 after the photo, applied against the repair if you proceed.
- Isolate and test. We confirm which device tripped, insulation-test the aircon circuit, then measure running and starting current against the circuit rating. No parts are swapped on a guess.
- Written quote. The fault, the fix and the price in writing before work starts. If the fault is inside the unit, the same company quotes the aircon work — one UEN, no finger-pointing between contractors.
- Repair and re-test. Circuit or unit repaired, then each circuit re-energised and tested one at a time, with the aircon run under load before we leave.
Hours are Monday to Saturday, 08:00–17:00, closed Sunday and public holidays. Regulated electrical work is carried out or supervised by an EMA Licensed Electrical Worker through our licensed consortium partners; no personal LEW number is published here.
Questions we get asked on WhatsApp
- Why does my power trip only when the aircon runs?
- Because the aircon is the only load on that circuit that combines a high starting current with water nearby. A compressor pulls several times its running current for a second at start-up, and a damp outdoor isolator or terminal box leaks current to earth as it runs. Both faults wait for the aircon to switch on.
- How do I know if it is the aircon or the wiring?
- Read the board. If the main RCCB with the test button drops and the whole flat goes dark, current is leaking to earth — commonly the unit, its isolator or a wet enclosure. If only that one MCB trips while the rest of the flat stays on, it is an overload or short on that circuit. An insulation test separates the two; a photo of the board narrows it before we arrive.
- Can I keep resetting the breaker to use the aircon?
- No. A breaker that trips has already detected a fault. Resetting it repeatedly, or wedging it closed, keeps that fault live — which is how scorched terminals and board fires start. Switch the aircon circuit off at the DB and leave the aircon off until it has been tested.
- Do I need a separate aircon contractor as well?
- No. AOT Electrical and AOT Aircon are the same company — ALPHA & OMEGA TRINITY PTE. LTD., UEN 201215586K — so the same firm can test the circuit and the unit instead of two contractors blaming each other. Regulated electrical work is carried out or supervised by an EMA Licensed Electrical Worker through our licensed consortium partners.
- What does it cost to find out?
- Diagnosis from S$60 after a photo of the DB with the tripped switch visible, applied against the repair if you proceed. If the fault is inside the aircon, general servicing starts from S$25 per unit and a chemical wash from S$80 per unit. Nothing is priced before the board and the unit are seen.